Concrete & Reinforcement Configuration Tests :  

 

Test of rebar for tensile strength  

InSitu Scanning test – Using Ferro Scan (Existing Rebar detection)  

Structural Design for check existing structure:

Analysis of sub soil investigations report.

Checking of structural stability and safety.

Checking of lateral load resistance capacity of the Building for earthquake and wind

Design check for soft story 

Checking of beam column joint detail for earthquake or other lateral load. 

 

WARESAT HUSSAIN RESIDENCE EXTENSION, UTTARA SEC -4

 

 

MR. NASIR RESIDENCE, ROAD 82, GULSHAN-2